UserName
Our extensive genomic solutions are trusted in our pursuit to improve the world. We understand your needs and can customize solutions to address your unique challenges.
Catalog Number 11380912
Catalog Number 16525231
Catalog Number 10794597
Catalog Number 15781198
Catalog Number 15869886
Catalog Number 15925322
Catalog Number 30057773
Conquering today’s genetic challenges can help shape a better future for us all. By offering an extensive range and scope of pioneering Applied Biosystems solutions, we bring tomorrow’s genetic revolution within reach.
Integrated sample preparation and RT-qPCR assay for quantitation of lentiviral proviral DNA in transduced cells.
Applied Biosystems TaqMan Gene Expression assays are used for quantitative real-time PCR analysis of gene expression and consist of a pair of unlabeled PCR primers and a TaqMan probe with a dye label (FAM) on the 5' end and a minor groove binder (MGB) and non-fluorescent quencher (NFQ) on the 3' end.
Shipping Condition | Room Temperature |
---|---|
GC-Rich PCR Performance | High |
Fidelity (vs. Taq) | 60 X |
Product Type | Gene Expression Assay |
Reaction Speed | Fast |
Green Features | Sustainable packaging |
PCR Method | qPCR |
Product Line | TaqMan™ |
Detection Method | Primer-probe |
Pre-formulated, optimized, universal 2X master mix for real-time PCR workflows.
Shipping Condition | Wet Ice |
---|---|
InhibitorToleranceSimple | Medium |
Concentration | 2X |
For Use With (Application) | Gene Expression |
PCR Method | qPCR |
Multiplex Capability | Single-plex |
Detection Method | SYBR |
Includes | dUTP, UNG/UDG |
Thermostability | 72 hr., Assembled Reaction |
Polymerase | Dual-Lock Taq DNA Polymerase |
Format | Tube |
Product Type | Real Time PCR SYBR Master Mix |
Passive Reference Dye | ROX (Pre-mixed) |
For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT System, QuantStudio™ 12k Flex, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio 6 Pro, QuantStudio 7 Pro, QuantStudio™ 7 Flex, QuantStudio™ Absolute Q Digital PCR System, StepOne™, StepOnePlus™, ViiA™ 7 System |
Sample Type | DNA |
Reaction Speed | Fast or Standard |
Target Specificity | cDNA or gDNA only |
Product Line | PowerUP™, SYBR™ |
Everything needed for SYBR™ Green dye-based PCR amplification and detection in a convenient, single-tube format.
Polymerase | AmpliTaq Gold DNA Polymerase |
---|---|
GC-Rich PCR Performance | High |
Format | Tube |
Product Type | Real Time PCR SYBR Master Mix |
Passive Reference Dye | ROX (Pre-mixed) |
Reaction Speed | Standard |
Label or Dye | SYBR Green |
Concentration | 2X |
For Use With (Application) | Gene Expression |
PCR Method | qPCR |
Product Line | SYBR™ |
Detection Method | SYBR |
The Applied Biosystems QuantStudio Absolute Q MAP16 Plate Kit is a key component of the QuantStudio Absolute Q Digital PCR System.
Accurate, real-time PCR-based pathogen detection in the presence of high levels of inhibitors.
Purity or Quality Grade | UP (Ultra Pure) |
---|---|
Concentration | 2X |
For Use With (Application) | Gene Expression,Genotyping,Pathogen Detection,Virus Detection |
PCR Method | qPCR |
Detection Method | Primer-probe |
Polymerase | AmpliTaq Gold DNA Polymerase |
Format | Bottle |
Product Type | qPCR Master Mix |
Passive Reference Dye | ROX (Pre-mixed) |
For Use With (Equipment) | 7000 System, 7300 System, 7500 Fast System, 7500 System, 7900HT Fast System, 7900HT System, StepOne™, Standard Mode |
Sample Type | Environmental Sample, Food |
Reaction Speed | Standard |
Hot Start | Built-In Hot Start |
Product Line | TaqMan™ |
Kit uses 3' poly-A tailing and 5' ligation of an adaptor sequence to extend the mature miRNAs present in the sample on each end prior to reverse transcription.
Used to maintain the ViiA™ 7, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6, QuantStudio™ 7, and QuantStudio™ 12K Flex real-time PCR systems with 96-well (0.2 mL) blocks.
The GeneScan™ 500 LIZ™ Size Standard is a fifth dye-labeled size standard for the reproducible sizing of fragment analysis data.
TaqMan Fast Virus 1-Step Master Mix is designed for fast, highly sensitive real-time RT-PCR, even in the presence of challenging PCR inhibitors.
Shipping Condition | Dry Ice |
---|---|
Reverse Transcriptase | M-MLV |
Form | Liquid |
InhibitorToleranceSimple | High |
For Use With (Application) | Microbial Detection,Gene Expression,DNA Quantitation,Presence/Absence |
PCR Method | 1-step RT-qPCR |
Multiplex Capability | Up to 3-plex |
Detection Method | Primer-probe |
Thermostability | Not Applicable |
Polymerase | AmpliTaq Fast DNA Polymerase |
Format | Tube |
Product Type | 1-Step Master Mix |
Passive Reference Dye | ROX (Pre-mixed) |
For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT System, QuantStudio™ 12k Flex, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio 6 Pro, QuantStudio 7 Pro, QuantStudio™ 7 Flex, QuantStudio™ Absolute Q Digital PCR System, StepOne™, StepOnePlus™, ViiA™ 7 System |
Sample Type | Total RNA, Viral DNA, Viral RNA, mRNA |
Reaction Speed | Fast or Standard |
Target Specificity | RNA only, Both RNA and DNA |
Hot Start | Built-In Hot Start |
Product Line | TaqMan™ |
The Applied Biosystems SeqStudio Cartridge is an all-in-one and easy-to-use reagent cartridge that includes capillaries, universal polymer, buffer, and pump required to run on the SeqStudio Genetic Analyzer System.
For use with MicroAmp™ TriFlex 3 x 32-Well PCR Reaction Plate
Offers superior sensitivity and reproducibility, detecting as few as two copies of a target gene over a broad range of template concentrations.
GC-Rich PCR Performance | High |
---|---|
Purity or Quality Grade | LD (Low DNA) |
Concentration | 2X |
For Use With (Application) | Gene Expression |
PCR Method | qPCR |
Detection Method | SYBR |
Polymerase | AmpliTaq Gold DNA Polymerase, AmpliTaq Gold LD |
Product Type | Real Time PCR SYBR Master Mix |
Passive Reference Dye | ROX (Pre-mixed) |
For Use With (Equipment) | 7300 System, 7500 System, 7700 System, 7900HT Fast System,Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, QuantStudio™ 12k Flex, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7, StepOne™, Standard Mode, StepOnePlus™, Standard Mode, ViiA™ 7 System |
Sample Type | DNA (Genomic), cDNA |
Reaction Speed | Standard |
Label or Dye | SYBR Green |
Product Line | SYBR™ |
This plate establishes the pure dye spectra and multicomponent values for FAM™, VIC™, ROX™, and SYBR™ dyes on Applied Biosystems™ QuantStudio™ 3 and 5 96-well 0.2-mL real-time PCR systems.
Provides the necessary components for 200 reactions of optimal performance in TaqMan™ MicroRNA Assays.
Shipping Condition | Dry Ice |
---|---|
GC-Rich PCR Performance | High |
Fidelity (vs. Taq) | 10 X |
Reverse Transcriptase | MultiScribe™ |
Final Product Type | cDNA |
Concentration | 10X |
For Use With (Application) | miRNA analysis |
PCR Method | 2-step RT-qPCR |
Detection Method | Primer-probe |
Size (Final Product) | 200 bp or less |
Reaction Format | Separate Components |
Product Type | MicroRNA Reverse Transcription Kit |
Sample Type | RNA |
Reaction Speed | Fast |
Optimal Reaction Temperature | 42°C |
Product Line | TaqMan™ |
Grandes ahorros en tecnologías avanzadas y ensayos de materiales.
Cada laboratorio tiene sus propios misterios. ¿Qué descubrirás? Acércate, busca lo que necesitas y descubre cómo la curiosidad puede llevarte a ahorros increíbles.
Cromatografía y productos químicos
Deje que sus genes hablen por sí solos con las Master Mix qPCR diseñadas para la ciencia de alto nivel.
Aprovecha esta oferta por tiempo limitado.
Utiliza el código promocional 24136 para conseguir un ahorro increíble.
No te pierdas nuestras rebajas de fin de año: ahorra hasta un 50% en equipamiento, instrumentación y servicios de laboratorio de primera calidad.
Ofrecemos grandes descuentos para una gran variedad de productos muy conocidos, como productos químicos, material esencial de laboratorio, productos para ciencias de la vida, equipos, consumibles y productos de seguridad.