Filtered Search Results
Mettler Toledo™ KCl 3M Electrode Filling Solution
Equipped with a special cap to facilitate easy filling of electrodes. Mettler Toledo™ KCl 3M Electrode Filling Solution is an electrolyte solution that enables optimum performance of pH and ion-selective electrodes. This bridge electrolyte contains no silver ions than can contaminate samples.
| pH Range | Neutral |
|---|---|
| For Use With (Equipment) | ARGENTHAL™ Reference System pH Electrodes, DX Series ISE Half Cells |
| Color | Colorless |
| Packaging | Bottle with Special Filling Cap |
| Concentration | 3 mol/L KCl |
| NIST Traceable | Yes |
Mettler Toledo™ Ribbon Ink Cartridge
For use with Mettler Toledo pH meters and printers.
Mettler Toledo™ FiveEasy™ F20 pH/mV Meters
Compact, benchtop meter provides high quality pH/mV measurements with simple click of a button
| Accuracy (mV) | ±1 |
|---|---|
| Memory | Current calibration |
| Resolution (pH) | 0.01 |
| Range (pH) | 0 to 14 |
| Calibration | Linear |
| Accuracy (pH) | ±0.01 |
| Temperature Compensation | ATC and MTC |
| Dimensions (L x W x H) | 22.7 x 14.7 x 7 cm (9 x 5.7 x 2.7 in.) |
| Display Type | LCD |
| Voltage | 120/240 V |
| Model | F20 |
| Resolution (mV) | 1mV |
| Frequency | 50/60 Hz |
| Temperature Range (English) | 32°F to 212°F |
| Weight (English) | 1.4 lb. |
| Resolution (Temperature) | 0.1°C |
| Temperature Range (Metric) | 0°C to 100°C |
| Range (mV) | 2000 to 2000 |
| Inputs | BNC, Cinch, NTC 30kiloOhm sensors |
| Accuracy (Temperature) | 0.5°C |
| Weight (Metric) | 0.63 kg |
Technical Buffer Solution pH 7.00, Mettler Toledo™
Greener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
Technical Buffer Solution pH 4.01, Mettler Toledo™
Greener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
Technical pH Buffer Solutions, METTLER TOLEDO™
Greener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
Provides a reliable all-around pH buffer. Mettler Toledo™ Technical pH Buffer Solution are specified to two decimal places and are traceable to NIST standards. Color-coded solution comes in a handy 250mL plastic bottle with no-fuss labels.
| For Use With (Equipment) | pH Electrode |
|---|---|
| Traceability to NIST | Yes |
| Quantity | 250 mL |
| Grade | Technical |
| For Use With (Application) | pH measurement, electrode calibration |
METTLER TOLEDO™ InLab™ Expert pH Electrodes
A combination pH electrode with PEEK plastic shaft for chemical and mechanical durability, and a fixed cable. Designed for use in a variety of applications.
| Diameter (English) | 0.47 in. |
|---|---|
| Length (Metric) | 120 mm |
| pH Range | 0 to 14 |
| Diameter (Metric) | 12 mm |
| Membrane | U Glass |
| Filling Solution Type | Xerolyt Polymer |
| Material | PEEK |
| Temperature (Metric) Operating | 0°C to 100°C |
| Internal Reference | ARGENTHAL |
Mettler Toledo™ Electrolyte for Reference Electrodes 3 mol/L KCl Sat AgCl, 250mL
Mettler Toledo™ Electrolyte for Reference Electrodes 3 mol/L KCl Sat AgCl, 250mL can be used to fill your electrode with correct and fresh electrolyte for precise measurement.
Mettler Toledo™ FiveEasy™ Plus FP20 pH/mV Meters
Compact, benchtop meter provides high quality pH/mV measurements with simple click of a button.
| Accuracy (mV) | ±1 |
|---|---|
| Memory | 200 measurements, current calibration |
| Resolution (pH) | 0.01, 0.1 |
| Range (pH) | -2 to 16 |
| Calibration | Linear/Segmented |
| Accuracy (pH) | ±0.01 |
| Temperature Compensation | ATC and MTC |
| Dimensions (L x W x H) | 22.7 x 14.7 x 7 cm (9 x 5.7 x 2.7 in.) |
| Data Management Details | RS232, USB |
| Display Type | LCD |
| Voltage | 120/240 V |
| Model | FP20 |
| Resolution (mV) | 1mV |
| Frequency | 50/60 Hz |
| Temperature Range (English) | 23°F to 221°F |
| Weight (English) | 1.4 lb. |
| Resolution (Temperature) | 0.1°C |
| Temperature Range (Metric) | -5°C to +105°C |
| Range (mV) | 2000 to 2000 |
| Inputs | BNC, Cinch, NTC 30kiloOhm sensors |
| Accuracy (Temperature) | 0.3°C |
| Weight (Metric) | 0.63 kg |
Buffer Solution Pack pH 4.01, 7.00, 9.21, Mettler Toledo™
Greener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
Mettler Toledo™ LE pH Electrode LE438-IP67 pH/Conductivity/DO Meter
IP67 waterproof, plastic pH electrode with integrated temperature sensor.
Mettler Toledo™ Moisture Analyzer Sample Pans
Mettler Toledo sample pans are the only sample pans that are officially supported by Mettler Toledo Moisture Analyzers for optimal use and guaranteed performance.
| Type | Moisture Pan |
|---|---|
| Shape | Round |
| Diameter (Metric) | 88.9 mm |
| Color | Silver |
| Bottom Shape | Flat |
| Autoclavable | Autoclavable |
| Sterility | Non-sterile |
Mettler Toledo™ InLab™ Sensor Cables: MultiPin™ Connection
Electrode cables to connect Mettler Toledo InLab sensors to any Mettler Toledo meter with compatible connector.
| For Use With (Equipment) | Mettler Toledo InLab Sensors |
|---|---|
| For Use With (Application) | To connect Mettler Toledo InLab sensors to any meter |
Mettler Toledo™ Peel-Off Self-Adhesive Labels for P50 Line Thermal Printers
For use with P50 Line Thermal Printers.
| Type | Peel-off Self-adhesive Labels |
|---|---|
| For Use With (Equipment) | P-56RUE and P-58RUE Thermal Printers |
Mettler Toledo™ 1M KNO3 Electrolyte Solution
Features a special cap for easy refilling of electrodes. Mettler Toledo™ 1M KNO3 Electrolyte Solution provides a bridge electrolyte for optimum performance of DX series Ion-Selective Electrode (ISE) half-cells. It is used for determination of ammonium, potassium and nitrate.
| Type | ISE Bridge Electrolyte Solution |
|---|---|
| pH Range | 6 |
| Color | Colorless |
| Concentration | 1 mol/L KNO3 |