Thermo Scientific™ POROS™ R1 Prepacked Reversed-Phase Columns

Código de producto. 18486698 Tienda Thermo Scientific Productos
Change view
Click to view available options
Tamaño de partículas:
10 μm
20 μm
Material:
PEEK
Stainless Steel
Dimensiones:
2.1 x 100 mm
2.1 x 30 mm
4.6 x 100 mm
4.6 x 50 mm
Cantidad:
1 Column
1 columna
Tamaño de la unidad:
cada uno
Código de producto. Tamaño de partículas Material Dimensiones Cantidad unitSize
18486698 20 μm Stainless Steel 4.6 x 100 mm 1 columna cada uno
18436758 10 μm PEEK 2.1 x 30 mm 1 columna cada uno
18416668 10 μm PEEK 2.1 x 100 mm 1 columna cada uno
18476698 10 μm PEEK 4.6 x 50 mm 1 columna cada uno
18406678 10 μm Stainless Steel 2.1 x 30 mm 1 Column cada uno
18496418 10 μm Stainless Steel 2.1 x 100 mm 1 columna cada uno
18456778 10 μm Stainless Steel 4.6 x 50 mm 1 columna cada uno
18476758 10 μm Stainless Steel 4.6 x 100 mm 1 columna cada uno
18466628 20 μm PEEK 2.1 x 30 mm 1 columna cada uno
18426428 20 μm PEEK 4.6 x 100 mm 1 columna cada uno
18486628 20 μm Stainless Steel 2.1 x 30 mm 1 columna cada uno
11 missing translation for 'options'
This item is not returnable. View return policy

Product Code. 18486698

missing translation for 'mfr': Thermo Scientific™ 1102426

Por favor, para comprar este producto. ¿No tiene usuario web? Regístrese hoy mismo.

This item is not returnable. View return policy

Thermo Scientific™ POROS™ Prepacked Reversed-Phase Column. POROS™ R1 is a 4000 angstrom pore size Poly[styrenevinylbenzene] particle, suitable for the reversed-phase separation of biomolecules.

POROS R1 is a 4000 angstrom pore size Poly[styrenevinylbenzene] particle, suitable for the reversed-phase separation of biomolecules. 10 micron particle size is used for the highest resolution chromatography, and is suitable for analytical to small scale preparative separation of biomolecules. 20 micron particle size is used for high resolution and small scale preparative to semi-preparative separation of biomolecules.

POROS High Performance Chromatography™ Media and Pre-Packed Columns

  • A high performance chromatography resins for analytical to process scale separations.
  • Higher productivity: High throughput and high dynamic capacity associated with High Performance Chromatography™
  • Chemical stability: Allows aggressive cleaning and sanitization
  • Enhanced biomolecule access: Provided via large pores, ranging between 500-10,000 Å
  • Polystyrenedivinylbenzene particles: Yield a robust, easily packable matrix
  • Develop better separations methods in a shorter time frame: The speed of High Performance Chromatography technology reduces weeks of experimentation to only a few hours of work, so you have plenty of time to explore all the variables of your separation

Reduce time-consuming sample prep

You can replace many sample preparation steps with high speed High Performance Chromatography technology. For instance, dialysis of large volumes of material can be replaced by high flow rate processing of the dilute sample. Elution in a small volume of new buffer accomplishes both buffer exchange and concentration.

Create novel assays for more efficient analysis

High Performance Chromatography technology is not limited to standard modes of separation. Both enzymes and affinity ligands can be immobilized on POROS media. By combining rapid on-column protein digestions with rapid on-column immunoassays and chromatographic separations, you can create entirely new assays with unlimited potential.

High capacity, high resolution, high speed

In contrast to conventional chromatography media, POROS High Performance Chromatography™ resins particles, are engineered to have two discreet classes of pores. Large 'throughpores' allow convection flow to occur through the particles themselves, quickly carrying sample molecules to short 'diffusive' pores inside. By reducing the distance over which diffusion needs to occur, the time required for sample molecules to interact with interior binding sites is also reduced. Diffusion is no longer limiting and flow rates can be dramatically increased - without compromising resolution or capacity. Separations can be achieved at 1000 to 5000 cm/hr compared to 50 to 360 cm/hr for conventional media.

Specifications

Formato de columna Preenvasados
Diámetro (métrico) 4.6 mm
Longitud (métrico) 100 mm
Presión máxima 2400 psi (170 bar)
Tamaño de partículas 20 μm
pH 1-14
Tamaño de poro 4000 Å
Cantidad 1 columna
Temperatura <110°C
Fase estacionaria Phenyl
Contenido y almacenamiento Almacenar a temperatura ambiente.
Línea de productos POROS
Capacidad de unión ~5 mg/mL (Lysozyme, 1% acetonitrile)
Condiciones de envío Temperatura ambiente
Volumen (métrico) 1.7 mL
Dimensiones 4.6 x 100 mm
Material de embalaje Highly Crosslinked Styrene-Divinylbenzene polymer (ST-DVB)
Tipo de columna Analítico
Material Stainless Steel
Técnica Bio-LC
Show More Show Less

For Research Use Only. Not for use in diagnostic procedures.