Learn More
Thermo Scientific™ Concentradores de proteínas Pierce™ con MWCO 9K
Tienda Thermo Scientific ProductosDescripción
Thermo Scientific™ Pierce Protein Concentrators are disposable centrifugal devices for high-performance concentration, diafiltration or buffer-exchange of biological samples.
Pierce Protein Concentrators effectively combine simplicity, speed, capacity and recovery to yield enhanced concentration, purification and separation of proteins even with dilute protein samples. The high-performance regenerated cellulose membranes in these 9K molecular-weight cutoff (MWCO) units are carefully and accurately rated to provide more than 90% protein recovery for proteins larger than 9000 daltons. Pierce Concentrators are available in 7mL and 20mL sizes, which are compatible with swinging-bucket and fixed-angle rotors. These centrifugal concentrators provide efficient concentration of biological samples containing proteins (antigens, antibodies and enzymes), nucleic acids (DNA) and micro organisms (viral particles).
Highlights:
Rapid protein concentration – achieve greater than 100-fold protein concentration in less than 45 minutes
Excellent protein recovery – remove buffer and small molecules while retaining more than 90% of proteins larger than 9kDa
Convenient – two sizes designed to fit 15mL and 50mL conical tubes; ideal for simple concentration of 1 to 20mL of sample
Instrument-compatible – use standard centrifuges with swinging-bucket or fixed-angle rotors; collect and recover sample without invert spinning
Versatile – the easiest way to perform sample concentration, diafiltration or buffer-exchange of biological samples
Requires:
Centrifuge equipped with a rotor for 15mL or 50mL conical tubes (for 7mL or 20mL Concentrators, respectively)
Recommended for:
Protein concentration with tissue culture media, antiserum or monoclonal antibody preps; Concentration of protein peaks following gel-permeation chromatography; Removal of unincorporated protein label; Concentration and desalt/buffer-exchange after eluting protein from ion-exchange, hydrophobic interaction (HIC), metal chelate or affinity chromatography columns.
Especificaciones
Especificaciones
| Descripción | Concentradores de proteínas Pierce, MWCO de 9K, 20 ml |
| Material (membrana) | Membrana de celulosa conectada al tubo de polipropileno |
| MWCO | 9000 Da |
| Cantidad | 10 dispositivos |
| Suficiente para | 10 muestras, cada una de 5 a 20 ml |
| Volumen (métrico) | 20 ml |
Al hacer clic en Enviar, acepta que Fisher Scientific se ponga en contacto con usted en relación con los comentarios que ha proporcionado en este formulario. No compartiremos su información para ningún otro fin. Toda la información de contacto proporcionada se mantendrá de acuerdo con nuestra Política de Privacidad. Política de privacidad.