Learn More
Invitrogen™ Mouse MCP-1 ELISA Kits
Descripción
Assay MCP-1 (mouse monocyte chemoattractant protein-1) levels in mouse serum, plasma (EDTA, heparin, sodium citrate) and culture supernatant samples with our Thermo Scientific™ Mouse MCP-1 ELISA Kits.
Target: Natural and recombinant mouse MCP-1 (monocyte chemoattractant protein-1)
Format: Colorimetric ELISA (TMB substrate) in clear 96-well strip plate
Measurement: Absorbance at 450nm minus absorbance at 550nm
Assay Range: 16 to 1000pg/mL
Sensitivity: < 4pg/mL
Precision: Intra-assay CV < 10%; inter-assay CV < 10%
Sample Types: Cell culture supernatant, serum, plasma (EDTA, sodium citrate and heparin)
Total Assay Time: 3 hours
Sample Size: 50μL
Specificity: No significant cross-reaction with mouse G-CSF, GM-CSF, IFNγ, IL-1α, IL-1β, IL-2, IL-3, IL-4, IL-5, IL-6, IL-7, IL-9, IL-10, IL-18, Eotaxin, MIP-1α, RANTES or TNFα, or human or rat MCP-1
Includes:Complete Kits contain pre-coated antibody-plates, detection antibodies, buffers, diluents, standards, and substrates. The Reagent Kit (previously called a “Screening Set”) contains matched antibodies, standard and detection reagents but no coated plates.
Especificaciones
Especificaciones
| Intervalo del ensayo | 16 to 1000pg/mL |
| Sensibilidad del ensayo | <4pg/mL |
| Descripción | Mouse MCP-1 ELISA Kit |
| Formato del kit de inmunoensayo | Colorimetric ELISA (TMB substrate) with Plates |
| Tipo de muestra | Cell Culture Supernatant, Plasma (EDTA, Citrate, Heparin), Serum |
| Especificidad | No significant cross-reaction with mouse G-CSF, GM-CSF, IFNg, IL-1a, IL-1ß, IL-2, IL-3, IL-4, IL-5, IL-6, IL-7, IL-9, IL-10, IL-18, Eotaxin, MIP-1a, RANTES or TNFa, or human or rat MCP-1 |
| Suficiente para | 96 microplate wells |
| Contenido del kit | TMB Substrate Solution, 12mL, Streptavidin-HRP Concentrate, 75 μL, Stop Solution, 13mL, 30X Wash Buffer, 50mL, Adhesive Plate Covers, 6 ea, Anti-Mouse MCP-1 Precoated 96-well Strip Plate, 1 ea, Biotinylated Antibody Reagent, 12mL, HRP Dilution Buffer, 13mL, Lyophilized Recombinant Mouse MCP-1 Standard, 2 vials, Sample Diluent, 12mL |
| Medición | Absorbancia a 450 nm menos absorbancia a 550 nm |
| Precisión | CV del intraensayo <10 %; CV del interensayo <10 % |
| Mostrar más |
Al hacer clic en Enviar, acepta que Fisher Scientific se ponga en contacto con usted en relación con los comentarios que ha proporcionado en este formulario. No compartiremos su información para ningún otro fin. Toda la información de contacto proporcionada se mantendrá de acuerdo con nuestra Política de Privacidad. Política de privacidad.