missing translation for 'onlineSavingsMsg'
Learn More

Applied Biosystems™ Detection Enhancer, for real-time PCR

Formulated to improve template amplification in real-time PCR (qPCR) workflows

12.58€ - 98.75€

Especificaciones

Método de detección Sonda de cebado
GC-Rich PCR Performance High
Método de PCR 1-step RT-qPCR
Velocidad de reacción Estándar
Para utilizar con (equipo) Sistema 7500
Ver más especificaciones

Productos 3
Código de producto Marca N.º de reacciones Precio Cantidad y disponibilidad  
Código de producto Marca N.º de reacciones Precio Cantidad y disponibilidad  
30057782
Ver documentos Detalles de la promoción
Applied Biosystems™
A44811
1000 x 25 μL Reactions
98.75€
1000 reacciones
Solo quedan null
Fecha estimada de envoi: 15-07-2025
Añadir a la cesta
 
30057791
Ver documentos Detalles de la promoción
Applied Biosystems™
A44941
500 x 25 μL Reactions
59.50€
500 reacciones
Por favor, para comprar este producto. ¿No tiene usuario web? Regístrese hoy mismo.
30054472
Ver documentos Detalles de la promoción
Applied Biosystems™
A44810
100 x 25 μL Reactions
12.58€
100 reacciones
Por favor, para comprar este producto. ¿No tiene usuario web? Regístrese hoy mismo.
Descripción

Descripción

  • Detection Enhancer is uniquely formulated to improve template amplification in real-time PCR (qPCR) workflows. This reagent is particularly beneficial with DNA samples containing GC-rich sequences and/or persistent secondary structure. Detection Enhancer is a component of the AgPath-ID One-Step RT-qPCR Reagents kit and is offered here as a stand-alone product that can be used with any Applied Biosystem real-time PCR master mix.
  • Improve qPCR amplification of templates containing high GC content and persistent secondary structure
  • Compatible with any Applied Biosystem real-time PCR master mix
  • Flexible kit sizes for a range of laboratory throughputs
  • GC-rich DNA sequences are usually defined as those that contain >60% cytosine (C) or guanine (G). GC-rich samples can be particularly challenging to amplify because the sequences are more stable than those with lower GC content. In qPCR experiments, this results in a higher DNA melting point. In addition, GC-rich sequences can form secondary structure, which can add further amplification challenges. Adding a small volume of Detection Enhancer to your reaction mix can dramatically improve qPCR amplification in GC-rich samples.
  • Detection Enhancer is specifically formulated to address qPCR amplification in particularly stable DNA sequences. It is only for use in real-time PCR workflows where amplification is affected by templates that are GC rich and/or contain persistent secondary structure. The reagents may affect sensitivity for other target types, so it is recommended to first assemble the reaction without Detection Enhancer. If no signal is observed from samples that are expected to be positive, then add Detection Enhancer to the reaction.
  • The recommended volume of Detection Enhancer per 25 μL reaction is 1.67 μL. For more information on applications of Detection Enhancer, please see the AgPath-ID One-Step RT-qPCR Reagents kit user guide
Especificaciones

Especificaciones

Sonda de cebado
1-step RT-qPCR
Sistema 7500
Detection Enhancer
Real Time PCR (qPCR)
High
Estándar
Applied Biosystems™
Dry Ice
Viral Samples
Videos
SDS
Documentos

Documentos

Product Certifications

Para uso exclusivo en investigación. No apto para uso en procedimientos diagnósticos.

Corrección del contenido de un producto

Proporcione sus comentarios sobre el contenido del producto rellenando el siguiente formulario.

Título del producto
Applied Biosystems™ Detection Enhancer, for real-time PCR

Al hacer clic en Enviar, acepta que Fisher Scientific se ponga en contacto con usted en relación con los comentarios que ha proporcionado en este formulario. No compartiremos su información para ningún otro fin. Toda la información de contacto proporcionada se mantendrá de acuerdo con nuestra Política de Privacidad. Política de privacidad.

Gracias por ayudarnos a mejorar nuestra web. Su comentario ha sido enviado