missing translation for 'onlineSavingsMsg'
Learn More
Learn More
Description
- Ready-to-use columns for convenient process development
- Rigid, highly cross-linked agarose matrix
- Bed height of 10cm is designed to allow method optimization and parameter screening
- Easily connected in series to achieve 20cm bed height
- Small bed volume (4.7mL) gives fast result and minimal sample/buffer consumption
- Reproducible results, scalable to BioProcess columns packed with the same chromatography media using the same linear fluid velocity
MabSelect
- For capture of MAbs from large sample volumes
- Prepacked with protein A-derived media
- Compatible with high flow rates and high pressure when scaling up
- Increased binding capacity enables purification of MAbs from high-level expression feedstock
- Also optimized for Fc-fusion proteins
- Very low, unspecific binding due to high ligand selectivity and matrix hydrophilicity
- Prepacked with protein A-derived media
- With novel, alkali-tolerant recombinant protein A ligand that provides greater stability and allows use of 0.1 to 0.5M sodium hydroxide for cleaning-in-place (CIP)
- Enhanced protease resistance resulting in lower ligand leakage
- High dynamic binding capacity
Specifications
Specifications
| Tampón | 8M Urea, 6M Guanidine Hydrochloride, 2% Benzyl Alcohol or 20% Ethanol |
| Tipo de columna | HiScreen MabSelect Prepacked Column |
| Descripción | Bed Dimensions: 7.7 × 100 mm |
| Incluye | Stoppers at the inlet and outlet |
| Tamaño del kit | 1 x 4.7mL |
| Soporte de cama | Filter |
| Diámetro interior (imperial) | 0.3 in. |
| Capacidad de unión | ≈30mg Human IgG |
| Diámetro interior (métrico) | 0.77cm |
| Tipo de producto | Columna preempaquetada HiScreen MabSelect |
| Show More |
Safety and Handling
Product Identifier
- HiScreen MabSelect
- Atención
- Líquido inflamable Categoría 3
- H226-Líquidos y vapores inflamables.
- P210-Mantener alejado del calor, de superficies calientes, de chispas, de llamas abiertas y de cualquier otra fuente de ignición. No fumar.
- P501b-Eliminar el contenido/el recipiente en conforme a la reglamentación local/regional/nacional/internacional.
- MIXTURE LIST-Contém: ethanol
Product Title
By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.
Spot an opportunity for improvement?