Invitrogen™ ProcartaPlex™ Human Substance P Competitive Simplex Kit

Código de producto. 31942172
Cambiar vista
Click to view available options
Cantidad:
96 Tests
Tamaño de la unidad:
96 tests
1 product options available for selection
Product selection table with 1 available options. Use arrow keys to navigate and Enter or Space to select.
Código de producto. Cantidad Tamaño de la unidad
31942172 96 Tests 96 tests
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 1 options available.
1 options
Este artículo no se puede devolver. Vea la política de devoluciones
Código de producto. 31942172 Proveedor Invitrogen™ N.º de proveedor EPX01012373901
 Artículo restringido
Fecha estimada de envoi: 16-09-2026
Añadir a la cesta
Añadir a la cesta
Este artículo no se puede devolver. Vea la política de devoluciones

The ProcartaPlex Human Substance P Competitive Simplex Kit measures Substance P protein and is based on competitive ELISA technique, where sample Testosterone competes with a labeled tracer for antibody binding, resulting in an inverse signal proportional to cortisol concentration.

The ProcartaPlex Human Substance P Competitive Simplex Kit measures Substance P protein and is based on competitive ELISA technique, where sample Testosterone competes with a labeled tracer for antibody binding, resulting in an inverse signal proportional to cortisol concentration.

This kit can be used for single-target quantification or combined with other simplex assays to create a panel. ProcartaPlex Competitive Simplex kits are compatible with each other and can also be combined with sandwich assays. Please use the Panel Configurator to verify the compatibility of your desired panel.

A ProcartaPlex Basic Kit (sold separately) is required to run the assay, as Simplex kits include only assay-specific components and do not contain any buffer or plate.

About ProcartaPlex Assays for the Luminex Platform

ProcartaPlex assays are bead-based immunoassays designed for multiplex protein analysis on Luminex™ xMAP instruments. They enable the simultaneous detection and quantification of multiple protein targets from a single, small-volume sample, helping researchers save time, sample, and cost compared to traditional single-analyte ELISAs.

Depending on the analyte, ProcartaPlex assays are based on either sandwich ELISA or competitive immunoassay principles.

  • Sandwich assays use two highly specific antibodies binding to different epitopes of the target protein.
  • Competitive assays measure small molecules or analytes with limited epitopes, where the sample analyte competes with a labeled tracer for antibody binding, resulting in an inverse signal.

How the technology works

ProcartaPlex assays use Luminex xMAP technology, in which microscopic magnetic beads are internally dyed with precise ratios of red and infrared fluorophores. Each bead population has a unique spectral signature and is coated with antibodies specific to a single target. This allows different analytes to be measured in parallel within the same well.

Unlike traditional ELISA, where antibodies are immobilized on a plate, ProcartaPlex reagents are free-floating in solution, improving reaction kinetics and enabling efficient multiplexing with the following benefits:

  • Multiplexing efficiency—measure up to 80 protein targets simultaneously
  • Low sample volume—as little as 25 μL for serum or plasma, or 50 μL for cell culture supernatant
  • Time-saving workflow—results in approximately four hours
  • High Throughput - 96-well and even 384-well assay formulations are available helping conserve valuable samples while increasing assay efficiency.

ProcartaPlex multiplex panels and simplex assays are available for six (species: human, mouse, rat, nonhuman primate, porcine, and canine).

For more information and a full list of available targets, visit thermofisher.com/procartaplex.

TRUSTED_SUSTAINABILITY

Especificaciones

Tipo de producto Magnetic Bead-based Assay
Cantidad 96 Tests
Especie Human
Combinability Combinable
Tipo de esfera Magnetic
Región de cordón Substance P [73]
Sensibilidad del ensayo As determined for Lot 1: 0.306 pg/mL
Intervalo del ensayo As determined for Lot 1: 800 to 0.2 pg/mL
Formato Simplex Kit
Para utilizar con (equipo) Luminex Instruments
génica TAC1
Alias de gen Tachykinin Precursor 1
ID de gen (Entrez) 6863
CV interensayo As determined for Lot 1: 12.3%
CV intraensayo As determined for Lot 1: 13.3%
Línea de productos ProcartaPlex
Tipo de muestra Serum, Plasma, Cell Culture Supernatants, Cerebrospinal Fluid
Volumen de muestra Serum, Plasma, CSF: 25 μL, CCS: 50 μL
ID. de UniProt P20366
Condiciones de envío Wet Ice
Research Area Endocrinology
Mostrar más Mostrar menos

For Research Use Only.

Título del producto
Seleccione un problema

Al hacer clic en Enviar, acepta que Fisher Scientific se ponga en contacto con usted en relación con los comentarios que ha proporcionado en este formulario. No compartiremos su información para ningún otro fin. Toda la información de contacto proporcionada se mantendrá de acuerdo con nuestra Política de Privacidad. Política de privacidad.